Search results for "sample preparation"
showing 10 items of 343 documents
Determination of90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry
1994
A new, fast technique for trace analysis of the radioactive isotopes89Sr and90Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the90Sr content in ≈ 870 m3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of90Sr was measured to be 1.4 mBq per m3, corresponding to 1.6 × 109 atoms of90Sr per sample. This value is in good agreement with the results…
Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?
2003
This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific …
The ways to the trace level analysis in infrared spectroscopy
2020
The future of infrared (IR) spectroscopy as an analytical technique is assured due to its versatility and its numerous advantages; such as the possibility to obtain molecular specific information for virtually any sample in any state with no treatment or minimal sample preparation. However, spectroscopists are not satisfied with relegating IR spectroscopy just to major and minor component analysis and have been looking at analysis at the trace level too. This review is the recognition of the brilliant research performed during the past two decades and the advances achieved in this area, which have made possible the analysis of contaminants at parts per billion (ppb) levels by IR in differen…
Analysis of thiabendazole and procymidone in fruits and vegetables by capillary electrophoresis–electrospray mass spectrometry
2002
Abstract A capillary electrophoresis–mass spectrometry method for determining procymidone and thiabendazole in apples, grapes, oranges, pears, strawberries and tomatoes is described. Separation is achieved using a buffer of formic acid–ammonium formate at pH 3.5 with 2% of methanol. Fungicide residues present in the sample are preconcentrated by both solid-phase extraction and injection of large sample volumes into the capillary by a stacking technique, to obtain lower detection limits. Ionization is performed at atmospheric pressure in an electrospray type source and detection is carried out using positive ionization and selected ion monitoring modes. The quantitation limits are 0.005 and …
Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring
2017
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …
Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.
2011
There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…
Improving the solid-phase extraction of “quat” pesticides from water samples
1998
A novel strategy, based on the addition of a cationic surfactant, for preventing the interferences associated with a diminution in the efficacy of solid-phase extraction (SPE) with silica cartridges of diquat, paraquat and difenzoquat in water is developed. Conditions for extraction are optimised with respect to pH, cationic surfactant and its concentration. Humic acids, anionic surfactants, inorganic salts and other organic contaminants like pesticides, phenols, polycyclic aromatic hydrocarbons and polychlorinated biphenyls produce the studied interferences. The best performance is shown in the improvement of the "quats" recovery from waters with high levels of humic acids and anionic surf…
A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations
2015
An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…
Determination of several aminoglycoside and macrolide antibiotics in animal tissues by liquid chromatography-electrospray ionization-tandem mass spec…
2008
Label-Free Proteomics of Quantity-Limited Samples Using Ion Mobility-Assisted Data-Independent Acquisition Mass Spectrometry
2021
Over the past two decades, unbiased data-independent acquisition (DIA) approaches have gained increasing popularity in the bottom-up proteomics field. Here, we describe an ion mobility separation enhanced DIA workflow for large-scale label-free quantitative proteomics studies where starting material is limited. We set a special focus on the single pot solid-phase-enhanced sample preparation (SP3) protocol, which is well suited for the processing of quantity-limited samples.